Timber: treatment is part of the care plan
For timber-clad buildings, our written guarantee requires a high-quality oil or spirit-based preservative within 30 days of installation, then at least once a year—inside and out.
This applies even though the timber is pressure-treated. A faded colour or water-beading test is not a substitute for the stated schedule.
Read the full guarantee conditions and the preservative manufacturer’s instructions. The product needs to be suitable for treated timber and its intended internal or external use. A decorative colour coat is not automatically a preservative: check compatibility before applying paint over treatment.
Keep a record of treatment dates and the products used. Treat any timber you cut, drill or notch at the exposed area, including the timber frame of a composite building. Keep window seals sound and follow the sealing requirements in the instructions and warranty.
Pressure treatment helps resist fungal decay and insect attack. It does not waterproof timber, prevent every crack or movement, or remove the need for care. The 15-year anti-rot warranty is subject to the written conditions; it is not a guarantee against every form of wear or accidental damage.
Composite cladding: no painting or preservative
The composite boards do not need timber preservative or painting. Wash away dirt using the board manufacturer’s approved cleaning method; avoid abrasive tools, harsh chemicals or close-range pressure washing unless expressly permitted.
The rest of the building still needs attention. Check the roof, drainage, glazing, seals, hinges and locks. Keep airflow underneath and around the structure clear. Follow the instructions for the timber floor and frame, and treat exposed cuts where required.
The 30-year manufacturer warranty relates to the composite cladding. The timber frame has its own 15-year anti-rot cover. Read the scope and conditions rather than treating the longest figure as cover for every component.
A useful rhythm through the year
Use these checks alongside the model’s instructions. An exposed coastal site or a building beneath trees may need more frequent attention.
01 · Spring
Inspect after winter
- Look at the roof covering and trims from ground level. Note lifting felt, damage, loose edges or signs of leaks.
- Clear accessible gutters and drainage routes safely. Keep vegetation and debris away from the walls and base.
- Inspect the floor, lower wall boards, door and glazing for damp or damage. Photograph anything that needs advice.
02 · Summer
Plan the annual treatment
- Treat timber-clad buildings at least annually, inside and out, following the preservative instructions. Choose suitable weather and allow the timber to dry as directed.
- Check hinges, locks and handles. Clean and lubricate according to the hardware instructions.
- Clean composite cladding with a suitable mild solution and soft brush. Test any cleaner on a small area first.
03 · Autumn
Keep water moving away
- Remove leaves and debris from around the base and accessible gutters. Check that water drains away after rain.
- Check the door closes without forcing it. Report persistent movement or a frame that no longer looks square.
- Keep stored equipment away from walls and vents. Dry wet tools and garden furniture before storing them.
04 · Winter
Check after storms
- Inspect from a safe position after strong winds, heavy rain or snow. Arrange repairs before a small defect spreads.
- Do not climb onto a shed roof or work from an unsafe ladder. For heavy snow, damage or anything out of reach, ask a competent professional.
- Air the building when conditions allow and keep designed ventilation clear. Investigate persistent damp rather than sealing every gap.
Quick checks between seasons
- There is no standing water against the building or beneath its floor.
- Roof covering, edge trims and accessible gutters look sound.
- Doors and windows operate without forcing; locks and hinges are secure.
- Vents are clear and stored items are not pressed against the walls.
- There are no new damp marks, soft areas, unusual smells or loose fixings.
Inspect from the ground where possible. Never stand on a shed roof, use a sharp tool to remove snow or apply an improvised repair over damaged covering. Arrange safe access and the right repair method.
See the everyday checks

Use the current written care requirements above and your model’s instructions alongside this general care video.
Fix the cause before covering the symptom
Persistent condensation can come from wet equipment, restricted ventilation, damp below the floor or a leak. Trace where moisture enters and how it leaves. Painting over mould or adding a heater without investigating the cause can leave the problem in place.
If the floor feels soft, the frame has moved, or the roof has been damaged, stop using the affected area and ask for advice. Send your order number and clear photographs through the support route. Speak to us before structural alterations or repairs that may affect warranty cover.